Improved electrical measurement method for junction temperature of light emitting diodes | Ulepszona metoda pomiaru temperatury zła{ogonek}cza diody LED

Kai Han,Muqing Liu,Shenglong Fan,Haiping Shen
2012-01-01
Abstract:The electrical test method (ETM) is used to measure the junction temperature T j of high brightness LEDs. NI 5922 digitizer and Keithley S2400 source meter were used to build the measurement system. Various measurement currents were used under 1MHz sampling rate. Results of different measurement currents are found to be the same under the same sampling rate and measurement error can be found under low sampling rates. When sampling rate is down to 0.2kHz, measurement error is up to 13.7%.
What problem does this paper attempt to address?