Sensorless Mover Position Estimation of Permanent Magnet Linear Synchronous Motor

WANG Li,LU Qin-fen,YE Yun-yue
DOI: https://doi.org/10.3969/j.issn.1007-449x.2012.06.002
2012-01-01
Abstract:In order to estimate mover position and speed of permanent linear synchronous motor(PMLSM) without position sensor,position sensing via flux linkage variation had been used.During the calculation,mean value of flux linkage was used twice to eliminate the flux linkage drift caused by open-loop electromotive force(EMF) integration instead of traditional filter,and dead-time compensation algorithm was adopted to reduce the difference between calculated and actual phase voltage.Control circuit was built to research air-cored PMLSM,estimation error was analyzed during the operation from 1Hz to 5Hz,and influence of motor parameters like resistance and inductance were analyzed finally.By measurement,root mean square error of mover position estimation reduced to 0.0240 rad at 3Hz.It is showed mover information of PMLSM could be obtained based on flux linkage variation.
What problem does this paper attempt to address?