Cogging torque research on Flux Reversal Machine based on FEM

GUO Liang,LU Qin-fen,YE Yun-yue,LI Guang-you
DOI: https://doi.org/10.3969/j.issn.1003-3076.2006.02.012
2006-01-01
Abstract:A novel double salient permanent magnetic machine,flux reversal machine(FRM),was introduced.Different from other common permanent magnetic machines,in the FRM,permanent magnets and coils were placed on the stator.So its rotor structure was very simple.Because of the advantages such as high power density,small induction and low inertia,etc.,the FRM was suitable for high speed applications.But this double salient structure also causes that the cogging torque in FRM is great,which can influence the smooth of the operation and the noise control.In order to reduce the cogging torque,in this paper,a 6/8 FRM was designed,and 2D finite element method was used to analyze the relationship between the cogging torque and the dimensions of the FRM such as tooth span,permanent magnet height and skewing angle.Then the prototype was manufactured.And the difference between the simulation and the experiment is about 8%,which shows that the FEM outcomes are accurate.