Determination of Content for Tacrolimus Ophthalmic Emulsion by HPLC and Prediction of Its Stability

WANG Yan-dong,TANG Xi-lan,YE Cheng-tian,WU Wei
2009-01-01
Abstract:AIM To establish the content determination method of tacrolimus ophthalmic emulsion and detect its stability. METHODS The separation was performed on Diamonsil C18 (250 mm × 4.6 mm,5 μm),the mobile phase was acetonitrile-water-phosphonic acid (600 ∶ 400 ∶ 1,V / V / V) with the flow rate of 2.0 mL· min-1,the detection wavelength was 215 nm and column temperature was 50 ℃. Its stability was studied by means of classic isothermal accelerated test. RESULTS The calibration curve of tacrolimus showed well linear correlation within the concentration range of 6.25 -200 mg·L-1,r = 0.999 9. The average retrievable rate of tacrolimus was (99.8 ± s 0.8)% (RSD = 0.59%),and the RSD of the repeatability test was 1.04% (n = 6). Its shelf life at 25 ℃ is about 122.6 days and would be 7.4 years under 4 ℃. CONCLUSION The HPLC method is simple,accurate and feasible. Tacrolimus ophthalmic emulsion should be stored under low temperature.