Discussion on some codes concerned with building foundation pit(Part 1)

Li Guangxin
2013-01-01
Abstract:Some questions and suggestions are proposed for "Code for Design of Building Foundation"(GB 50007-2011),"Technical Specification for Retaining and Protection of Building Foundation Excavation"(JGJ120-2012) and other local codes which are promulgated recently.This paper is the first part of a series of discussion papers.The application of strength parameters of soil in the calculation of earth pressure and stability analysis is discussed and some suggestions are as follows:(1) for granular soil,the CD strength parameters are applicable;(2) for cohesive soil,the CU strength parameters are reasonable.The use of UU strength conforms to the principal of effective stress,but the correct determination of cu value is difficult which increases with the depth;(3) the pre-consolidated UU strength parameters under effective gravity stress is questionable because it is confused in concept and inapplicable in practice;(4) for normal consolidated clay in pit engineering,under slow construction and good drained conditions,rather than CU strength parameters,CD strength parameters is suitable;(5) in soft clay,the calculation of the earth pressure induced by construction overcharge on ground surface and the checking of the heaving of pit bottom should be calculated by using of UU strength parameters not by CU strength parameters.
What problem does this paper attempt to address?