Determination Four Active Ingredients of Extraction from Scutellaria Baicalensis Georgi by HPLC

DING Fang-lin,ZHANG Wen-jie,CHEN Bo,YAO Shou-zhuo
DOI: https://doi.org/10.3969/j.issn.1006-060X.2008.03.047
2008-01-01
Abstract:To establish a HPLC method for determination of baicalin,baicalein,wogonoside and wogonin in extraction Scutellaria baicalensis Georgi.The analytical column was Spherigel-C18 column(5 μm,4.6×200 mm).The mobile phases was 0.2 % HAc(A)-methanol(B) at a flow rate 1.0 ml/min.Gradient elution,0-30min: B 42%-70%.The detection wavelength was 276 nm.The 1inear ranges of baicalin,wogonoside,haicalein and wogonin were 0.500~2.00 μg(r =0.9 996),0.66~3.30 μg(r =0.9 995),0.55~2.75 μg(r =0.9 998),0.51~2.55 μg(r =0.9 994).The average recoveries(n=5) of baicalin,wogonoslde,baicalein and wogonin were 98.32%,99.17%,101.25,102.53,respectively;RSD were 2.65%,2.48%,1.92%,3.04%,respectively.The method is simple,accurate and can be used to determine active ingredients of extraction from Scutellaria baicalensis Georgi.