Optimization design of the ventilation requirement characteristics and air outlet layout of multi-storied garage

Sun Yongqiang,Zhang Xu,Wang Jun
DOI: https://doi.org/10.3969/j.issn.1002-8501.2010.04.019
2010-01-01
Abstract:Based on the current theory of garage ventilation at home and abroad,analyses the air distribution effects under different ventilation rates and air outlet configuration and the requirement characteristics at partial pollution load by means of CFD methodology.The results show that the ventilation rate of multi-storied garage can be estimated with single vehicle displacement method and that the diluted concentration method is recommended;the exhaust outlets should be installed on the upper part of the garage for effectively removing of pollutants.Moreover,the proportion of outdoor air requirement for partial pollution loads is higher than that of the pollution load.