Experimental measurement method of sensitivity matrix for electromagnetic tomography

Liu Ze,Xue Fangqi,Yang Guoyin,Xing Zhe,Sun Xiufang
DOI: https://doi.org/10.19650/j.cnki.cjsi.2013.09.010
2013-01-01
Abstract:Sensitivity matrix is the prior information of image reconstruction in electromagnetic tomography system,which indicates the output variation of detectors when the small test objects are placed one by one in the reconstruction section of the electromabnetic tomography imaging system.In order to get higher image reconstruction quality,the reconstruction section is usually divided into a large number of mesh elements for sensitivity calculation and reconstruction result expression;therefore the sensitivity matrix of electromagnetic tomography is commonly calculated by solving the forward problem with electromagnetic field finite element simulation method.Nevertheless,the finite element simulation forward problem model is hardly consistent with the real model.This difficulty affects the precision of prior information and the quality of image reconstruction.Different from traditional sensitivity acquisition method,this paper designs an experimental measurement method of the sensitivity matrix.The sensitivity data are measured automatically on each element by using a precision step motor driven moving stage to move the test object according the coordinate of the mesh obtained from the finite element software.Then,the sensitivity matrix is calculated from the automatically measured results.The image reconstruction results verify the effectiveness of this sensitivity measurement method.
What problem does this paper attempt to address?