Plasma Pharmacokinetics, Tissue Distribution and Excretion Study of 6-Gingerol in Rat by Liquid Chromatography-Electrospray Ionization Time-Of-Flight Mass Spectrometry

Wei Wang,Chang-Yin Li,Xiao-Dong Wen,Ping Li,Lian-Wen Qi
DOI: https://doi.org/10.1016/j.jpba.2009.01.020
IF: 3.571
2009-01-01
Journal of Pharmaceutical and Biomedical Analysis
Abstract:A rapid resolution liquid chromatography coupled with electrospray ionization (ESI) time-of-flight mass spectrometry method was developed and validated for quantitative analysis of 6-gingerol in plasma and various tissues. Liquid-liquid extraction was employed as sample preparation technique. Biological samples were separated on an Agilent Zorbax StableBond-C(18) column (4.6 mm x 50 mm, 1.8 microm) and detected by TOF/MS with electrospray ionization (ESI) interface in positive ion mode. Calibration curves (1/x(2) weighted) offered satisfactory linearity (r(2)>0.995) within the test range. The lower limit of quantification in different matrices was in a range of 10-100 ng/mL. Inter- and intra-day precision were in the range of 0.91-11.90% and 0.75-10.23%, respectively. Recoveries in plasma, urine and tissues ranged from 72.5% to 90.4%. Glucuronide of 6-gingerol, the major metabolite of 6-gingerol, was further determined after beta-glucuronidase hydrolyzation. This developed method was successfully applied to pharmacokinetics, tissue distribution and excretion studies of 6-gingerol after oral or intraperitoneal administration in rats.
What problem does this paper attempt to address?