Improvement of Small Bowel Transplantation Rat Model under Microscopy

Han Zhiqiang,Wang Yu,Wang Zhigang
DOI: https://doi.org/10.3969/j.issn.1007-6948.2007.04.027
2007-01-01
Abstract:Objective To improve the method of operation about small bowel transplantation(SBT) model in rats Methods Both operations of the donor and that of the recipient were performed under microscopy.The graft removed consisted of the proximal jejunum,portal vein(PV) and the sleeve of abdominal aorta(AO) with superior mesenteric artery(SMA).Arterial end-to side anastomosis was performed between the donor sleeve pf abdominal aorta with SMA and the recipient abdominal aorta.Venous end-to end anastomosis was performed between the donor portal vein and the recipient left renal vein by muff,on the transplanted intestine were made two stoma at both ends.Results Formal experiments were operated for 100 times,and the ratio of successful operations was 91%.The time of operation on the donor was limited within 50 min and that on the recipient was done within 80 min,the total operation time was about 150 min.Conclusion The established method of improving SBT model in rats under microscopy has the advantages such as clear view and accurate orientation in operation,limited local injury,shorter operative time,fewer complications and higher survival rate.
What problem does this paper attempt to address?