Improvement of Rat Model of Orthotopic Left Lung Transplantation

ZHU Hong-wei,WU Jing-xiang,XU Mei-ying
DOI: https://doi.org/10.3969/j.issn.1674-8115.2011.03.007
2011-01-01
Abstract:Objective To improve the cuff-like vessel anastomosis technique-based rat model of transplantation,and establish a simple and stable rat model of orthotopic left transplantation. Methods Based on preliminary experiments,improvement was made from cuff-like vessel anastomosis technique-based rat model of transplantation on the following aspects: lungs were extracted from donors through median sternotomy,and were perfused through cut at the cone of the pulmonary artery with low pressure;blood vessel clamps were used to fix the rear part of pipe;micro left auricular clamps were used to clamp hilum instead of removing sick lung to complete tallies;respiratory tract management was enhanced.The new model was evaluated by successful rate of operation,time of operation,transplanted function and pathological changes. Results Ten consecutive rat models of orthotopic left transplantation were completed,with the successful rate of 80%.The time of donor perfusion-harvest,donor vessel anastomosis and recipient vessel anastomosis was(12±2) min,(18±3) min and(31±3) min,respectively.The oxygenation index 15 min after reperfusion was significantly higher than that 30 min after single ventilation(P0.05).The typical pathological changes of ischemia-reperfusion injury were confirmed by pathological examinations 2 h after reperfusion. Conclusion The improved rat model of orthotopic left transplantation has been successfully established,which is simple and effective.