Numerical Simulation on Suction Performance of Steam Turbine Hollow Stationary Blade

WANG Xin-jun,LIAO Gao-liang,ZHU Ding,YAO Jin-ling,BAI Xiao-wei,WANG Zhan-chi
DOI: https://doi.org/10.3969/j.issn.1001-5884.2012.03.011
2012-01-01
Abstract:The steam field within hollow stationary cascade in the last stage of a 600MW steam turbine and the slot-suction performance blade were simulated with the CFD software Fluent.The effects of the slot structure parameters on the suction performance were discussed.The results show that with the slot position varying from foreside edge to trailing edge of blade,the steam mass flux sucked by slot located on the convex side decreased rapidly,but the steam mass flux sucked by slot located on the concave side increased slightly to the maximum at the slot relative position ψ=0.723 4,and then decreased gradually.As the degree of slot increased,the steam mass flux sucked became larger and then smaller,the maximum value occurred at angle 45 which accounted for about 1.8% of the total mass flux passing the cascades channel.As the width of the slot increased,the steam mass flux sucked decreased to the minimum value at width of 2.0 mm and then increased.In addition,the slot suction ability had connection with the volume of inner hollow region,vortex nucleus position in the inner hollow region,vortex core radius and the streamline length of suction working substances.