Experimental Study of the Effect of Suction Slot Location on Water Removal Performance of Hollow Stationary Blades

Xin-jun WANG,Cheng LU,Jian-cheng LIU,Jun-bo ZHANG
DOI: https://doi.org/10.3969/j.issn.1001-2060.2007.05.002
2007-01-01
Abstract:On the slot suction test rig of a humid-air plane-cascade, an experimental study was conducted of the water removal performance of the suction slots on hollow stationary blades of a steam turbine. The test conditions are given as follows: the air humidity at the cascade inlet, 7.94%; water droplet diameter, between 1.5 to 150 μm, airflow velocity at the cascade outlet, 170 m/s; width of the suction slot, 1.0 mm, angle of the suction slot 45° with the suction slots being located at the suction and pressure side of the stationary blades respectively. The test results show that with an increase in relative location of the suction slots, the water quantity sucked through the slots will increase and under a same suction pressure difference, the water quantity sucked through a unit length of a slot on the concave surface of a stationary blade is greater than that on the convex surface. The suction slots close to the water outlet on the concave side of a stationary blade enjoy an optimum water-removal performance. Furthermore, with an increase of the suction pressure difference, the water quantity sucked through the slots will also increase accordingly.