The Application of Echocardiography to Guide Interatrial Septal Puncture and Evaluate the Clinical Effect in Percutaneous Balloon Mitral Valvuloplasty

马依彤,王朝霞,黄定,武云,穆玉明,唐琪
DOI: https://doi.org/10.3969/j.issn.1004-8812.2006.06.009
2006-01-01
Abstract:Objective To explore the application of echocardiography to guide interatrial septal puncture and evaluate the clinical effect in PBMV. Methods One hundren and sixty two patients were categorized into two groups according to whether echocardiography was applied in atrial septal puncture and real time monitoring. X-ray fluoroscopy guidence was used during atrial septal puncture in group 1 and in group 2, X-ray as well as echocardiography were used. The clinical outcomes were analyzed and contrasted between the 2 group. Results (1) The mean mitral pressure gradient dropped obviously in group 2 immediately after PBMV compared with group 1 (6.4±2.6 mm?Hg vs 10.2±3.7 mm?Hg,P0.05). (2) The mitral valve area (MVA) increased obviously after the procedure in group 2 compared with the pre-operational area as well as with that of group 1 two days after the procedure. (3) The incidence of post-operational mitral valve regurgitation (MVR) and pericardiac tamponade was lower in group 2 compared with group 1 (P0.05). Conclusion Echocardiography plays an important role in guiding interatrial septal puncture and clinical monitor. It can improve the clinical outcomes of PBMV and reduce the complications.