Comparison of electrostatic collection and liquid impinging methods when collecting airborne house dust allergens, endotoxin and (1,3)-β-d-glucans

Maosheng Yao,Huili Zhang,Shuofei Dong,Shiqi Zhen,Xiaodong Chen
DOI: https://doi.org/10.1016/j.jaerosci.2009.02.002
IF: 4.586
2009-01-01
Journal of Aerosol Science
Abstract:The use of electrostatic collection was investigated in quantifying airborne environmental allergens and toxins. The experiments were conducted with two 96-well plates filled with water and placed into the electrostatic sampler designed in this study. The combinations of different electrostatic fields: 0.63, 1.25kV/cm, and different sampling flow rates: 5, 12.5L/min, were tested with the electrostatic sampler. As a reference, a BioSampler operating at 12.5L/min was simultaneously placed in the same environments. The sampling lasted for 40min both for electrostatic sampler and the BioSampler in each test. House dust allergens, endotoxin and (1,3)-β-d-glucans in the air samples collected were analyzed using enzyme-linked immunosorbent assay (ELISA) and Limulus amebocyte lysate (LAL) method, respectively. The entire experiments were conducted both in office environment and hotel rooms.