Treatment of Cathodic Electrocoating Wastewater by Coagulation and Ceramic Membrane Filtration

ZHANG Jin,DONG Qiang,SUN Yuxin,LIU Xingqin,MENG Guangyao
DOI: https://doi.org/10.3969/j.issn.1007-8924.2006.06.012
2006-01-01
Abstract:Treatment of cathodic electrocoating wastewater by coagulation and microfiltration with zirconia membrane(mean pore size of 0.2 μm) was studied in this paper.The effects of operating parameters,such as pH on the COD removal,transmembrane pressure,crossflow velocity on the membrane flux were investigated.The method for membrane cleaning and suitable operating parameters were proposed.The results indicated that the removal of COD was 63% at pH of 6.7 and with Lime as coagulant,and followed by microfiltration the removal of COD increased to 85%.At a cross flow velocity of 4.2 m/s,trans-membrane pressure of 0.10 MPa,and the steady flux is about 250 L/(m~2·h).The results of filtration tests showed that the membrane fouling decreased and the permeate flux and permeate quality increased with coagulation as pretreatment.The permeate obtained from coagulation and micro-filtration can be used as rinsing water in electrocoating process or discharge.The flux recovered to 80% of the initial value after the cleaning of the membrane.
What problem does this paper attempt to address?