Improved determination of saturate, aromatic, resin, and asphaltene (SARA) fractions using automated high-performance liquid chromatography approach
Shadi Kheirollahi,Mabkhot BinDahbag,Hadi Bagherzadeh,Zahra Abbasi,Hassan Hassanzadeh
DOI: https://doi.org/10.1016/j.fuel.2024.131884
IF: 7.4
2024-05-29
Fuel
Abstract:Fractionation of complex hydrocarbon mixtures such as bitumen into their constituents based on their polarizability and solubility is essential in the detailed characterization of petroleum fluids. The development of fast and reliable analytical techniques for petroleum characterization has been the focal point of fractionation studies. The separation of Saturate, Aromatic, Resin and Asphaltene (SARA) fractions using our previously reported automated fractionation technique relied on material balance in estimating the saturates, which could introduce inherent errors in determining all fractions. Furthermore, the previous technique was developed using concentrated samples, which could exacerbate the material balance error. Here, we have improved and optimized our previously developed technique to address these shortcomings. This enhancement involves full automation of the analytical detection process for all fractions and optimizing the measurement operation, sample concentration, and volumes. This led to the development of a fully automated analytical instrument and optimized technique for rapidly and efficiently separating and detecting four subfractions of complex hydrocarbon mixtures, including saturates, aromatics, resins, and asphaltenes. In this technique, only 50 μ L of a sample with an oil concentration of 0.006 g/ml is required for separating oil SARA fractions by injecting through three columns packed with specific stationary phases. Initially, the asphaltene separation occurs in a ground polytetrafluoroethylene (PTFE) packed column in an excess volume of n-pentane. Then, the pentane-soluble maltene passes through standard ZORBAX RX-SIL- and ZORBAX CN-packed columns, where chromatographic separation of the resins and aromatics occurs. The highly polar resins are adsorbed on the ZORBAX CN column, whereas the moderately polar components (i.e., aromatics) are retained on the ZORBAX RX-SIL column. The saturate fraction is not retained on the columns and is directed to the refractive index detector (RID) for quantification. After separating each fraction, in the last step, asphaltenes, aromatics and resins are eluted from their respective columns by injecting toluene and forwarded to an ultraviolet − visible (UV − vis) absorbance to quantify each fraction. The results of the SARA-HPLC technique exhibited excellent accuracy and reproducibility; the average deviation of saturate, aromatic, resin, and asphaltene fractions are 1.29, 2.81, 3.75, and 1.04 wt%, respectively. This technique delivers SARA fractionation results with high repeatability within 1.65 wt% average deviation. The enhanced automated approach for SARA separation demonstrates superior efficiency by employing less concentrated samples, reduced volumes of oil samples and solvents, and significantly shorter testing times compared to the conventional gravimetric manual method.
energy & fuels,engineering, chemical