Determination of Hydrocortisone in Compound Povidone Iodine Gel by HPLC

江喜春,程广龙,王海瑞,张华林,熊家军,滑国华,杨利国
DOI: https://doi.org/10.3969/j.issn.1002-1280.2010.03.001
2010-01-01
Abstract:Hydrocortisone in compound povidone iodine gel was determined by HPLC with C18(4.6 mm×250 mm,5 μm) as chromatography column,mobile phase consisting of acetonitrile:methanol:ammonium acetate(20∶ 45∶ 35).The detection wavelength was 240 nm and the flow rate was 1 mL·min-1 at 37℃of the column temperature.The results showed that there was a good linear relationship within the hydrocortisone concentration range of 0.025~0.122 mg·mL-1(r=0.999 3),and the recovery rate was 96.06% with relative standard deviation(RSD) of 0.45%.The test indicated that the method of HPLC was sensitive,rapid and accurate for detecting the hydrocortisone in compound povidone iodine gel,and it can be used for quality control or check up analysis of this compound preparation.
What problem does this paper attempt to address?