Effect of Abutments, and Denture Support Forms on the Prosthetic Outcome of Telescope Dentures

甘红,张修银,许晓岑,钱晨
2009-01-01
Abstract:Objective:To evaluate the effect of the condition of abutments and the denture support forms on the outcome of telescope dentures.Methods:38 cases restored with telescope dentures were included.The clinical investigation for the condition of abutments,such as the number,the crowns and the periodontal condition of the abutments,the denture support forms and the dental prosthesises were conducted and the results were statistically analysed with Fisher's Exact Test.Results:Most abutment fractures occurred in the cases of free-end arches with 1-2 abutments than those with 3 or more than 3 abutments.Abutment fractures mostly occurred in anterior teeth and premolars closed to free-end edentulous aeras,especially for premolars.Both abutment fractures and base plate fractures occurred in the cases of free-end arches more than those of non-free-end arches.As abutments,the falling post-core-crown of the residual root and residual crown fractures were more than those with periodontitis or with a small number of abuments(P0.05).Conclusion:For telescope dentures,at least 2 abutments on both sides of the arch should be chosen.
What problem does this paper attempt to address?