Clinical outcome of Bryan artificial cervical disc replacement for the treatment of cervical spondylosis: A midterm follow-up
Chen Ding,Hao Liu,Tao Hu,Rui Shi,Tao Li,Ying Hong,Yue-ming Song,Li-min Liu,Jian-cheng Zeng,Qing-quan Kong
DOI: https://doi.org/10.3969/j.issn.1673-8225.2011.17.004
2011-01-01
Abstract:BACKGROUND: Although the short-term clinical efficacy of Bryan artificial cervical disc replacement is generally acknowledged by most spinal surgeons, the midterm and long term clinical results and complications are still unclear. OBJECTIVE: To summarize midterm term clinical results of Bryan artificial cervical disc replacement for the treatment of cervical spondylosis. METHOD: From November 2004 to December 2007, 34 patients had Bryan cervical disc replacement in Department of Orthopedics, West China Hospital were selected, including 30 cases with single replacement and 4 cases with bi-level replacement. Clinical result was evaluated by SF-36 score, JOA score, and neck/arm pain VAS scores. And the data was collected before surgery and at 7 days, 3, 6, 12, 24, 36 and 48 months after surgery. Neutral lateral and dynamic cervical radiographs were made to measure the flexion-extension range of motion (ROM) of operative segment, adjacent segments and C2-7 segment, the intervertebral height of operative and adjacent segments, and the translation of operative level. The intraoperative and postoperative complications were recorded and analyzed. RESULTS AND CONCLUSION: The neurological symptoms of each patient were alleviated notably. The postoperative SF-36 physical component score and SF-36 mental component score, JOA score, NDI score and neck/arm pain VAS scores were significantly improved compared with those of the preoperative (P < 0.05), but no statistical significance were noted between each time point after 3-month follow-up (P > 0.05). Each implanted prosthesis preserved the ROM>2° at each follow-up time point, and no heterotopic ossification or spontaneous fusion was found at the operative segment. At 48-month follow-up, flexion-extension ROM of operative segment and C2-7 segment slightly increased but showed no statistical significance compared with the preoperative counterparts (P > 0.05); ROM of upper and lower adjacent segments also showed no statistical significance compared with the preoperative data (P > 0.05). Intervertebral height of operative segment was (6.04±1.02) mm before the operation and significantly increased to (8.44±0.43) mm at 48-month follow-up (P < 0.05). Intervertebral height of adjacent segments, and the translation of operative level were not significantly changed (P > 0.05). The clinical result of Bryan artificial cervical disc replacement is good and kinematic characteristics of operative segment, adjacent segments and C2-7 segment can be maintained in midterm follow-up. The operation is safe and there are few early midterm complications.