Energy Dissipation and Vibration Reduction of the Biaxial-symmetric Two-tower-connected Structure with Fluid Viscous Dampers

Wu Yaohui,Lou Yu,Li Aiqun
2008-01-01
Abstract:Based on the load-bearing and deforming behavior of the biaxial-symmetric tuo-tower-connected structure,the fluid viscous dampers are used at the location of the connecting part to dissipate energy and reduce the vibration of the structure.The variation of the structure response with the changing damping factor is analyzed and an optimized damping factor is found to achieve minimum structural response.By optimizing the damping factor,the vibration reducing effect of viscous fluid damper on the structure is investigated in detail under both large and small earthquakes.The calculation has shown that by applying optimal damping factor,satisfactory vibration reducing effect can be obtained in terms of major structural parameters,such as the maximum shear force between stories,relative displacement between stories and story displacement.However,due to the increasing damping ratio after the structure enters plastic phase under a large earthquake,the energy dissipation ratio of the dampers will relatively decrease,therefore,the vibration reducing effect will not be so notable as that of the dampers under a small earthquake.
What problem does this paper attempt to address?