Preliminary Application of a Novel MRI Micro-Coil for Small Rodent Animal

许永华,方磊,杨利霞,丁爽,黄自丽,潘晓东
2012-01-01
Abstract:【Objective】To evaluate the usefulness and feasibility of a homemade micro-coil applied with clinical MRI(cMRI)for small rodent animal imaging research.【Methods】The gene knock down mouse brain,nude mouse with a human-colon-cancer xenograft model,and fatty mouse abdomen underwent Siemens Avanto 1.5T MRI applied with 25mm micro-coil.TSE T2WI was performed for the anatomic mouse brain,TSE T1WI,T2WI,diffusion weighted imaging(DWI) and dynamic contrasted enhancement for xenograft model and chemical shift imaging(CSI) for fatty liver detection as well as MRS for abdominal lipids on fatty mouse model.【Resluts】The cortex thickness,corticomedullary demarcation,thalamus and ventricles of the gene knock-down mouse brains were clearly displayed on T2WI with high resolution and signal noise ratio(SNR).Subcutaneous human-colon-cancer xenograft tumors on nude mice were shown with high SNR and water molecular DWI,and the tumor vessel permeability was detected by DCE.The hepatic and abdominal adipose of fatty mice was detected by CSI and quantitatively analyzed by MRS.【Conclusion】The clinical high field MRI combined with 25 mm micro-coil might image mouse brain,subcutaneous xenograft on nude mouse with high resolution and SNR of anatomical structures as well as molecular and functional imaging and quantitatively analysis.It would provide the reliable and accurate image information for basic science.
What problem does this paper attempt to address?