Off-design Characteristics of Three-pressure with Reheat Bottom Cycle System in Integrated Gasification Combined Cycle

CHEN Xiao-li,WU Shao-hua,LI Zhen-zhong,WANG Yang,WANG Ying,CHEN Lei
DOI: https://doi.org/10.13334/j.0258-8013.pcsee.2010.23.014
2010-01-01
Abstract:The model of 200 MW integrated gasification combined cycle (IGCC) system was established by the software ThermoFlex. The off-design characteristics of three-pressure with reheat bottom cycle system in IGCC were studied and effects of gas turbine’s load, atmosphere temperature and air separation unit (ASU) integrated coefficient on characteristics of bottom cycle system were fully discussed. Results show that while in regulation manner of adjusting compressor inlet guide vanes (IGV) angle and keeping turbine inlet temperature (T3) constant to reduce gas turbine’s load, main steam temperature and reheat steam temperature are firstly increased and then declined. Closing IGV angle can restrain pressure of high-pressure vapor-bag decline, and make exhaust steam dryness of low-pressure steam turbine rise, so this is beneficial to improve off-design characteristics of bottom cycle system. As atmosphere temperature increasing, pressure of high-pressure vapor-bag, steam flow inlet high-pressure cylinder and power of bottom cycle system all decline, but main steam temperature and exhaust steam dryness of low-pressure cylinder in steam turbine increase. Decreasing Xas can greatly enhance power of bottom cycle system, but slowly reduce exhaust steam dryness of low-pressure cylinder in steam turbine.
What problem does this paper attempt to address?