Electroanalysis of uric acid at a boron-doped diamond electrode modified with cysteine

Li Xiao-li,Wu Jing,Shen Guo-li,Yu Ru-qin
DOI: https://doi.org/10.3969/j.issn.1008-2298.2006.02.009
2006-01-01
Chemical Sensors
Abstract:A boron-doped diamond electrode (BDDE) electrochemically modified with cysteine was used for monitoring uric acid (UA) by cyclic voltammetry (CV) and square wave voltammetry (SWV). Owing to the distinct ability of the modified boron-doped diamond electrode to yield its best performance, the major obstacle in monitoring UA was overcome from the interference from ascorbic acid (AA) and dopamine coexisting with each other owing to the well-defined performance of BDDE. There are different peak potentials between UA and AA or dopamine at the modified boron-doped electrode, moreover, the modified BDDE exhibited superior electrochemical properties that the peak current of UA was in direct proportion to scan rate, indicative of a surface confined reduction process and that obtain a sensitive amperometric response for UA which covered linearly from 1.45×10-9 mol/L to 1.16×10-6 mol/L under the optimum conditions with good stability and satisfactory detecting results.
What problem does this paper attempt to address?