Single-Atom Ruthenium Biomimetic Enzyme for Simultaneous Electrochemical Detection of Dopamine and Uric Acid

Xiaoli Xie,Dong Ping Wang,Chunxian Guo,Yuhang Liu,Qianghai Rao,Fangming Lou,Qiannan Li,Yongqiang Dong,Qunfang Li,Hong Bin Yang,Fang Xin Hu
DOI: https://doi.org/10.1021/acs.analchem.0c05191
IF: 7.4
2021-03-10
Analytical Chemistry
Abstract:Single-atom catalysts have attracted numerous attention due to the high utilization of metallic atoms, abundant active sites, and highly catalytic activities. Herein, a single-atom ruthenium biomimetic enzyme (Ru-Ala-C<sub>3</sub>N<sub>4</sub>) is prepared by dispersing Ru atoms on a carbon nitride support for the simultaneous electrochemical detection of dopamine (DA) and uric acid (UA), which are coexisting important biological molecules involving in many physiological and pathological aspects. The morphology and elemental states of the single-atom Ru catalyst are studied by transmission electron microscopy, energy dispersive X-ray elemental mapping, high-angle annular dark field–scanning transmission electron microscopy, and high-resolution X-ray photoelectron spectroscopy. Results show that Ru atoms atomically disperse throughout the C<sub>3</sub>N<sub>4</sub> support by Ru–N chemical bonds. The electrochemical characterizations indicate that the Ru-Ala-C<sub>3</sub>N<sub>4</sub> biosensor can simultaneously detect the oxidation of DA and UA with a separation of peak potential of 180 mV with high sensitivity and excellent selectivity. The calibration curves for DA and UA range from 0.06 to 490 and 0.5 to 2135 μM with detection limits of 20 and 170 nM, respectively. Moreover, the biosensor was applied to detect DA and UA in real biological serum samples using the standard addition method with satisfactory results.The Supporting Information is available free of charge at <a class="ext-link" href="/doi/10.1021/acs.analchem.0c05191?goto=supporting-info">https://pubs.acs.org/doi/10.1021/acs.analchem.0c05191</a>.XPS wide scan survey of Ru-Ala-C<sub>3</sub>N<sub>4</sub>; XRD pattens of samples and BET of Ru-Ala-C<sub>3</sub>N<sub>4</sub> and Ru-C<sub>3</sub>N<sub>4</sub>; cyclic voltammetry curves of Ru-Ala-C<sub>3</sub>N<sub>4</sub>, Ru-C<sub>3</sub>N<sub>4</sub>, Ala-C<sub>3</sub>N<sub>4</sub>, and C<sub>3</sub>N<sub>4</sub> with 100 μM DA and 200 μM UA; current response of Ru-Ala-C<sub>3</sub>N<sub>4</sub> toward 100 μM DA and 200 μM UA in 0.1 M PBS with different pH values from 6.5 to 9.0; amperometric response of Ru-Ala-C<sub>3</sub>N<sub>4</sub> for sample detection (<a class="ext-link" href="/doi/suppl/10.1021/acs.analchem.0c05191/suppl_file/ac0c05191_si_001.pdf">PDF</a>)This article has not yet been cited by other publications.
chemistry, analytical
What problem does this paper attempt to address?