Abstract:Objective To explore the feasibility of applying the visual colorimetric test strips to monitor capillary blood glucose levels.Methods Both visual colorimetric test strips and rapid blood glucose monitor were used to measure the capillary blood glucose levels.The visual values were read by patients and nurses at the same time for the same blood sample.Results The determination was conducted in 201 patients on the same blood sample.There were no significant difference between the values of rapid blood glucose monitor and visual colorimetric test strips by patients and nurses.The results of visual colorimetric test strips were not influenced by the patients'age(P>0.05).Conclusion Visual colorimetric test strips can accurately reflect patients' capillary blood glucose levels,which is not influenced by the patient's age.