A Simplified way to manufacture high-Q microfiber coil resonators by controlling the input/output coupling

Fei Xu,Peter Horak,Gilberto Brambilla
2007-01-01
Abstract:The dependence of the Q-factor of the microfiber coil resonator on different input/output couplings is investigated and compared. A method of slowly varying input/output coupling is presented to considerably simplify the fabrication of high-Q resonators. The microfiber coil resonator (MCR) is a promising functional device for compact all-fiber circuits. I n particular, with the most recent developments in th e manufacturing technology of ultra-low loss microf ibers (1- 3), MCRs could potentially compete with the highest Q-factors currently achieved only in whispering ga llery resonators (4). An MCR can be created by wrapping an optical microfiber on a low-index dielectric rod and its geometry cannot be achieved by planar technology. However this type of resonator presents a grave issu e: the extremely high sensitivity of the Q-factor to the c oupling strength, which in turn has an exponential relation with the pitch. If ultra-high Q-factors can be achieved over a large range of coupling coefficients, the ma nufacture of high-Q MCRs is considerably simplified. In this pap er we present a simple method to achieve high-Q MCRs over a wide range of coupling coefficients by tunin g the coupling between the coil and the input and o utput pigtails. Our analysis of the MCR is based on the solution of coupled wave equations. Consider the propagation of light along an MCR, as illustrated in Fig.1. Along the fiber, we define the amplitude of the field at the mth turn as Am(θ), 0 < θ <2π. Ignoring coupling between turns that are not adja cent to each other, the propagation of light along the coil in a M-turn MCR is described by the coupled wave equations for slowly varying pitches (5,6): where K( ϕ) is the coupling coefficient (5) between neighboring turns along the coil and ϕ=θ +( m-1)·2 π. K assumes values between 0 (no coupling) and KM (maximum coupling for touching fibers). Field cont inuity between the turns implies that Am+1 (0)=A m(2 π)exp(i2R πβ), m=1,2…M-1, where β is the propagation constant and R is the coil radius. The amplitude transmission coe fficient is defined as T=A M(2 π)/A 1(0)exp(i2R πβ) and the Q- factor as Q= λ0/∆λ, where ∆λ is the full width at half maximum (FWHM) of resonances in T. Fig. 2 shows the dependence of the FWHM on constant K(ϕ)=K near λ0≈1.55 μm for a MCR with M= 4. The microfiber is assumed to have 800nm radius, 0.02dB/mm loss and R=125/2 �m. The FWHM fluctuates widely. Therefore, high Q-factors cannot be obtained simply by targeting the highest K, i.e. by making two adjacent turns touching. In principle, the highest Q-factor can be achieved by selecting a K for which the FWHM is minimized, but in practice this is difficult to rea lize because K is very sensitive to the distance between adjacent turns. For the ease of fabrication it is therefore desirable that the FWHM is at its minimum and changes slowly with K. To quantify this behavior a new parameter, the to lerance ratio (TR), is introduced and defined as th e
What problem does this paper attempt to address?