Anatomical study of endoscopic transsphenoidal pituitary surgery assisted by navigation

Gong Jian,Jia Ge,Li Chunde
2010-01-01
Abstract:Objectives To assess the application of navigation system in endoscopic transsphenoidal pituitary surgery.Methods Endoscopic transsphenoidal surgery was performed on 20 head cadavers including 10 assisted with GE-InstaTrak 3500 electromagnetic navigation and 10 without navigation.The important anatomical landmarks and structure variants were measured and analyzed statistically in order to assess the system accuracy.Surgical outcome and security were compared between surgeries assisted with and without navigation.Results The systematic error of GE electromagnetic navigation was 0.28 ±0.06 mm and the actual procedural error was 1.5±0.5 mm.The average time for installing and setting up the navigation system was 11.9±2.0 min.In normal anatomical condition,there was no statistical difference in the operation time between surgeries assisted with and without navigation.When anatomical variations existed,the operation time was significantly shortened by a navigation system.Conclusions The endoscopic transsphenoidal pituitary surgery via navigation system can provide fast and precise localization in the cases with undefined anatomical relationships such as anatomical variations and post multiple surgeries,and make the surgery safer and more efficient.