Temperature Load Analysis for Structural Design of Conservatory at Gardens by the Bay,Singapore

Yong-jiu SHI,Yang GAO,Yuan-qing WANG,Yang JIANG,Zhao-yi ZHANG,Guo-xing LI
DOI: https://doi.org/10.13849/j.issn.1006-6578.2010.04.009
2010-01-01
Abstract:Arch-reticulated shell hybrid steel structure was adopted in the conservatories at gardens by the bay in Singapore.As the internal forces and deformations caused by temperature variation could exert great impact on the structural safety,the temperature load can not be ignored in structural design.Because temperature load had led to far higher stress of shell frames near the arch-reticulated shell connections than the standard,the fully rigid welded joints in the original proposal were thus replaced by pinned spring joints in the initial stage of design.Two kinds of FEA software were employed to analyze static response under both day condition and ignition condition.Comparative analysis of stresses and deformations was carried out on load cases with temperature load considered or not,which verified the importance of temperature load in design of large-span steel structure.
What problem does this paper attempt to address?