Energy-dissipation design of Sushang Building in Suqian

Dai Yaping,Yuan Xuefen,Liu Weiqing,Wang Shuguang,Du Dongsheng,Lian Haoliang
DOI: https://doi.org/10.19701/j.jzjg.2013.20.020
2013-01-01
Abstract:A detailed analysis of the whole energy-dissipation design procedures of Sushang Building in Suqian was provided. First of all,the equivalent damping ratio and the number of damping walls were calculated according to the given target displacement. Then the PERFORM-3D program was adopted to perform the time-history analysis under the frequent earthquake level,and the dynamic elasto-plastic analysis under the rare earthquake level as well,both analyses were performed to evaluate the seismic performance of the overall structure. The performance of the critical components was evaluated as well. Meanwhile,the comparative analysis between the energy-dissipated structure and the non-energydissipated structure shows that the former structure has capability to undertake greater elasto-plastic deformation and greater strength under rare-earthquakes.
What problem does this paper attempt to address?