Study and Evaluation of the Lighting Performance of LED Luminaires for the Interior Zone of Qiantang River Tunnel

Liu Ying,Zhang Xingjun,Su Weiping,Wang Tao,Li Qing,Long Tianguang,Zhou Xiaoli,Liu Muqing
DOI: https://doi.org/10.3969/j.issn.1004-440X.2013.01.012
2013-01-01
Abstract:Based on the advantages of LED lighting source,the tunnel lights of the interior zone of Qiantang River tunnel is planned to adopt LED lighting.And LED tunnel luminaires(A,B,C,and D) from four manufacturers were installed,and their performances are evaluated.With recording the illuminance data of each measurement point on the road for about 4308 hours,we found that luminare B has the highest illuminance degradation of 4.6%,whereas luminaire C has the lowest illuminance decay of 1.9%.In order to evaluate the measurement stability,we used another illuminometer to performe comparison test.ANVOA(analysis of variation) analysis result shows that the lighting environment,spectrum of the luminaire,testing stuff etc.,can influence the illumination results and luminaire A,D have better measurement stability than that of luminaire B and C.
What problem does this paper attempt to address?