Comparison and Application of Mesopic Models under the Tunnel Environment

Mengsheng TONG,Chi ZHANG,Tianhang ZHANG,Dengchao QIAN,Cheng KANG,Ke WU
DOI: https://doi.org/10.3969/j.issn.1004-440X.2017.06.022
2017-01-01
Abstract:The present research analyzes the differences between the luminance calculated using the USP,S,MOVE,MES2 model and its causes,as well as discusses the applicability of each model in tunnel lighting from the perspective of visual conditions.Results show that in the interior zone of the tunnel,luminance calculated by MOVE ranks the highest,followed by MES2 and S model,and USP ranks the lowest.The major difference among visual performance based systems is adaptation coefficient x.Meanwhile,visual tasks with chromatic,high contrast and large eccentricity can enhance the weight of photopic function V (λ) in mesopic function Vm (λ);while visual tasks with achromatic,low contrast and small eccentricity can strengthen the weight of scotopic function V'(λ).The chromatic,eccentricity below 5 degrees,negative and positive contrast target is more frequently encountered in tunnel.Thus,MOVE model is more applicable to describe the actual vision in the tunnel driving environment.
What problem does this paper attempt to address?