Study of Ultrasound Controlled Release of Fibrinolysis in Vitro Hematoma Through the Release of the Urokinase - Extended Release Dosage System

SUN Wei,Liu Weidong,DUAN Yourong,MAO Qing,QI Xuelian,QIAN Zhongxin,Gong Liang,Zhao Mingzhu
DOI: https://doi.org/10.3969/j.issn.1008-6978.2008.01.001
2008-01-01
Abstract:Objective To evaluate the efficacy and safety of ultrasound(US)activation of the release of urokinase(Uk)- extended release dosage system on fibrinolysis in vitro hematoma.Methods Prepare the urokinase loaded in PluronicP-105 micelles (Np).One milliliter(ml)human blood clots were produced by adding an 30 ml fresh blood into tube and incubating in a water bath at 37℃for 2 hours.The clots were transferred to tubes and divided into 6 groups:①Sodium Chloride(Ns)+Uk;②Ns+Uk+US;③Np -Uk;④Np-Uk+US;⑤Np-Uk+Ns;⑥Np-Uk+Ns+US.The residual hematoma volumes were calculated by the exact transfer- pettor on the devised time(6,12,24,48,72h,4,7,14d).Results The residual hematoma volumes of Np-Uk+Ns+US groups were decreased significantly than that of the other groups(P0.001).There was no significant difference in control groups(P0.05).The residual hematoma in the Np-Uk group and the Np-Uk+Ns group were no difference in 6h and 12h,but there was sig- nificant difference in 24,48 and 72 h(P0.001).Conclusions The ultrasound can activate the release of Uk loaded in PluronieP- 105 micelles,which could be more effective and safe than the common Uk in the fibrinolysis of vitro hematoma.
What problem does this paper attempt to address?