Determination of Arsenic and Mercury in Tobacco by Atomic Fluorescence Spectrometry

Huang Yun,Fan Ying,Meng Zhaoyu,Miao Mingming,Zhao Qihua,Yang Guangyu
DOI: https://doi.org/10.3969/j.issn.1672-8513.2007.02.021
2007-01-01
Abstract:In this paper,the determination of arsenic and mercury in the tobacco by atomic fluorescence spectrometry(AFS) was studied.The samples were digested by nitric acid and hydrogen peroxide in a microwave oven,and the arsenic and mercury were determined by atomic fluorescence spectrometry.Under the optimal conditions,the relative standard deviations were below 2.8% for mercury and 2.5% for arsenic,the standard recoveries were 93% for mercury and 96% for arsenic.The detection limits were 0.035μg/L.This method is accurate,rapid,convenient,and applicable.
What problem does this paper attempt to address?