Optimum passage arrangement for multi-stream plate-fin heat exchanger in various conditions through genetic algorithm

Hu Yunyun,Xiao Wu,He Gaohong
DOI: https://doi.org/10.3969/j.issn.1001-4160.2012.01.003
2012-01-01
Abstract:Optimization of passage arrangement,which directly influence the heat transfer effect and the structure compactness of heat exchanger,is the core problem in the design of plate-fin heat exchanger.In the traditional plate-fin heat exchanger design,the passage arrangement is usually designed at a single maximum load operation point,which ignores the impact of heat transfer when the operation point changes very much.But in fact the operation conditions change along with seasons,raw materials and production circumstances,which usually lows the plate-fin heat exchanger's heat transfer when it works at these operation points.The number of the passage arrangement increases exponentially with the increase of fluid number in the plate-fin heat exchanger,so the passage arrangement is determined according to the experiential rule,which needs designers spend a lot of time in repeatedly improving the heat exchanger's passage arrangement to comply with the design requirements,and achieve superior heat transfer effect.To overcome this shortcoming,a novel flexible design method was presented in the paper based on flexible design of passage arrangement for multi-stream plate-fin heat exchanger in various conditions.The objective function was the minimum mean-square deviation of accumulative heat load of the passage arrangement,and genetic algorithm(GA) was adopted to attain the optimal passage arrangement.Specific steps:1) GA was used to achieve the best passage arrangement at every operation point;2) Flexible design was used to combine the different best passage arrangements to get flexible design passage arrangement which can worked well at all operation points;3) Fine-tuning strategy was used to improve flexible design channel arrangement to get the final optimal passage arrangement by reducing the mean-square deviation of accumulative heat load.Finally an illustrative example was presented to demonstrate the validity and advantages of the proposed approach,the final passage arrangement's average mean-square deviation of accumulative heat load of three different operation points was 3632.48 W,which was lower than that of literature 3660.72 W.This approach improved the design speed greatly,reduced the designers' work load,and achieved the flexible optimal design of plate-fin heat exchanger.
What problem does this paper attempt to address?