DETERMINATION OF THIAMPHENICOL CONCENTRATION IN CHICKEN PLASMA BY HPLC WITH INTERNAL STANDARD

Zhang Xiaohua,Tao Guanhong,Chen Yuan,Chen Xiaolan
DOI: https://doi.org/10.3969/j.issn.1008-6145.2010.02.013
2010-01-01
Abstract:The blood concentrations in chicken of thiamphenicol were determined by the HPLC internal standard method,after the plasma containing florfenicol as the internal standard was extracted by acetonitrile.The chromatographic column was Shim-pack CLC-ODS column(150 mm×6 mm,5 μm),the mobile phase was acetonitrile-water(25∶75) at a flow rate of 1.0 mL/min,the detecting wavelength was 225 nm,and the column temperature was 40℃.In the chromatographic conditions,the calibration curve of thiamphenicol had a good linearity within a concentration range of 0.25-32.00 mg/L(r=0.999 9) and the detection limit was 0.1 μg/mL.The intra-day and inter-day RSD(n=5) were less than 6.1% at low,medium and high concentration levels.The extraction recoveries were more than 98.68% and the method recoveries were 99.20%-100.25%.The method can meet the analysis requirements of biological samples,and it can be used for the study of clinical thiamphenicol pharmacokinetic.
What problem does this paper attempt to address?