Hemodynamic changes in liver measured by multi-imaging methods before and after transjugular intrahepatic portosystemic stent-shunt
Yong Huang,Wei Chen,Jia Ping Li,Wen Quan Zhuang,Zi Ping Li,Jian Yong Yang
DOI: https://doi.org/10.3760/j.issn:1005-1201.2007.12.019
2007-01-01
Abstract:Objective To evaluate hemodynamic changes in liver treated by transjugular intrahepatic portosystemic stent-shunt(TIPSS)with hepatic computed tomography(CT)perfusion,Doppler ultrasound and portal vein pressure measurement,as well as the correlation among these methods.Methods Hepatic CT perfusion was performed in 9 cirrhotic patients one week before TIPSS and 72 hours after TIPSS. Intraoperative portal vein pressure was measured before and after portosystemic shunt establish.The follow- up hepatic CT perfusion were carried out in 3 cases at 3 months and 6 months postoperatively.The hemodynamic surveillance by Doppler ultrasound were performed in 48 hours and 3 months after TIPSS for 9 cases,and in 6 months after TIPSS for 6 cases.Two cases underwent venography and portal vein pressure measurement in 6 months after TIPSS treatment.Results The mean of portal vein perfusion(PVP),total hepatic blood flow(THBF),hepatic perfusion index(HPI)and portal vein free pressure(PVFP)before TIPSSwere(0.92±0.18)ml·min~(-1)·ml~(-1),(1.28±0.17)ml·min~(-1)·ml~(-1),(28±8)%,and (23.92±0.86)mmHg,respectively.In 72 hours after TIPSS,the mean of PVP,THBF,HPI and PVFP were(0.21±0.15)ml·min~(-1)·ml~(-1),(0.74±0.18)ml·min~(-1)·ml~(-1),(74 +13)%,and (12.62±1.54)mm Hg,respectively.After treatment,the mean of PVP was(0.49±0.05)ml·min~(-1)· ml~(-1)at 3 months and(0.57±0.03)ml·min~(-1)·ml~(-1)at 6 months,respectively.There was negative correlation between PVP and PVFP before TIPSS(r=0.678,P0.05),but there was no correlation between them after TIPSS(r=0.543,P0.05).Moreover,a signifieant correlation was found between the degree of portal vein pressure decrease and portal vein perfusion decrease(r=0.867,P0.01).In addition,the mean of blood flow rate(BFR)of portal vein detected by Doppler ultrasound after TIPSS in 48 hours were as follows:(27.9±3.4)cm/s for the main portal vein,(62.6±6.4)cm/s for the within stent,(18.9±7.2)cm/s for the left branch of portal vein,(6.6±3.2)cm/s for the right branch of portal vein,respectively.The mean of blood flow of stent(15.6±1.1)cm~3/s was not less than that of main portal vein(9.83±5.72)cm~3/s until six months after treatment.Conclusion The portal vein pressure obviously decreased after TIPSS,and meanwhile,most blood flow of portal vein passed through portosystemic stent shunt without liver parenchyma perfusion.Moreover,the more the portal vein pressure decreased,the more the inefficient blood flow of portal vein was.Hepatic arterial perfusion could not balance the decrease of efficient PVP.