Effect Analysis of Quartz-Lamp Holder Blind Area of Radiation Heater to Heat Flux Field

Fanjin KONG,Xiaofeng YIN,Wei ZHANG,Baorui LIU,Hao CHENG
DOI: https://doi.org/10.3969/j.issn.1006-3919.2013.03.008
2013-01-01
Abstract:Quartz lamps are widely used as the radiation heater in thermal testing. But, because of the lower working temperature of the lamp holder, the blind area would appear at the junction of two quartz lamps so that the heat flux on the relative areas of samples would be declined. Based on Monte Carlo method, both the effects of the blind area size and the distance between lamp-array and sample on heat flux field of sample were investigated, and the means to improve the heat flux field under the influence of blind area was proposed. The research could be used for the design of heater layout;thereby the performance of the thermal testing will be improved.
What problem does this paper attempt to address?