Establishing and Evaluating of Mouse Closed Femur Fracture

张连方,齐进,王晋申,钱念东,周琦,杨军,邓廉夫
2010-01-01
Abstract:[Objective]To develop a standard closed experimental fracture model in mouse femur.[Method]A 0.45 mm stainless-steel rod was introduced into the medullary cavity and the pre-nailed femur shaft was fractured by an impact device,which resulted in a reproducible transverse fracture pattern.The fractures were examined using X-ray Micro-CT,and histological method.[Result]Transverse fractures were created in 91.67% of the experimental mice,and the fracture healing was typical secondary fracture healing.[Conclusion]The standard closed fracture model in this experiment,whose healing was typically secondary fracture healing,can be obtained easily and used in study of fracture.
What problem does this paper attempt to address?