Flow Analysis of End-to-End Femoral Bypass Graft

QIAO Aike,LIU Youjun,ZHANG Song
DOI: https://doi.org/10.3969/j.issn.1002-3208.2006.04.005
2006-01-01
Abstract:In the conventional end-to-side femoral bypassing surgery, the sharp change of geometry configuration of anastomosis inevitably results in the nonuniform flow. Blood flow from the graft strongly strikes on the floor of anastomosis and influence the surgery effectiveness. In order to improve this phenomenon,end-to-end anastomosis configuration is proposed. The blood flow in the end-to-side and end-to-end models was simulated with numerical method. For the sake of comparison, these two models were constructed with identical geometry parameters, and imposed with identical boundary conditions. The numerical simulation was performed with finite element method of computational fluid dynamics. The results depicted the temporal and spatial distributions of hemodynamic variables such as flow patterns, wall shear stresses and wall shear stress gradients. The comparison indicated that end-to-end model was featured with larger longitudinal velocity, smaller secondary flow, more uniform wall shear stress etc. versus the end-to-side model. Thus, the end-to-end model was of more favorable hemodynamics and would decrease the probability of intimal hyperplasia and restenosis.
What problem does this paper attempt to address?