Simulation Studies of Doppler Ultrasound Blood Flow Signals from Bypassed Coronary Arteries

Xi Xiangjun,Wang Yuanyuan,Zhou Hu,Wang Weiqi
DOI: https://doi.org/10.3969/j.issn.1674-1242.2007.02.001
2007-01-01
Abstract:To explore the correlation between blood flow conditions and geometric factors for a bypassed coronary artery,a simulation method based on the computational dynamics models is employed to generate the Doppler ultrasound blood flow signals from bypassed coronary arteries with different grafting angles and distances.The variation of the simu- lated signal spectrum following that of the two factors is analyzed.Results show that the spectral bandwidth decreases with smaller angles at the toe and downstream of the anastomosis,thus the graft may have better post-operative effect.It is also seen that with a shorter grafting distance,the bandwidth increases near the heel of the anastomosis,however decreas- es at the toe and downstream area,which suggests a compromise in positioning the graft.Since analysis results are consis- tent with the outcomes of hemodynamic studies,they may be helpful to the coronary bypass surgery planning and the eval- uation of the post-operative effectiveness by the Doppler ultrasound technique.
What problem does this paper attempt to address?