The Value of B Ultrasound,MSCT and MRCP in Diagnosis of Biliary Diseases
FANG Chang-hai,DENG Ke-xue
DOI: https://doi.org/10.3969/j.issn.1006-5741.2012.06.009
2012-01-01
Abstract:Purpose:To study the diagnostic value of B ultrasound,64-slice spiral CT and MRCP in biliary obstructive diseases.Methods:The prospective case-control study was performed and the criteria for every case into the group were as follows:?Every patient underwent these three methods;?Every case was confirmed by pathology or a comprehensive examination result of the biliary obstructive disease.From October 2010 to October 2011,a total of 96 cases were obtained,including 24 cases of bile duct stones,11 cases of cholangitis stenosis,15 cases of chronic pancreatitis,3 cases of congenital choledochal cyst,9 cases of hilar bile duct carcinoma,6 cases of common bile duct carcinoma,13 cases of pancreas head carcinoma, 5 cases of ampulla carcinoma,and 10 cases of gallbladder carcinoma.The images of the B ultrasound,CT and MRCP were analyzed,and the results of them were compared.Results:The accuracies of B ultrasound, MSCT and MRCP in evaluating the nature of benign diseases were 79.2%,96.2%,92.5%,respectively. The accuracies in evaluating the nature of malignant diseases were 76.7%,97.7%,93.0%,respectively.The total accuracies in evaluating the nature of biliary diseases were 78.1%,96.9%,92.7%,respectively.The total accuracies in evaluating the site of biliary diseases were 86.5%,97.9%,99.0%,respectively.Conclusion: The accuracy of three methods for diagnosis of obstructive diseases were different and every methods has advantages and disadvantages,so comprehensive imaging methods were recommended in clinical applications.