Complication of manual small-incision cataract surgery

MAI Wei-hu,DENG Hong,CHEN Yun-fei,HUANG Xiao-bo,XIE Qing,CHEN Hui
DOI: https://doi.org/10.13210/j.cnki.jhmu.2011.01.041
2011-01-01
Abstract:Objective:To analyze the cause and treatment of complication during manual small-incision cataract surgery(MSICS).Methods:Clinical data of 142 eyes with MSICS were collected and analyzed.Results:During surgery,15 eyes(10.6%)had envelop rupture,9 eyes(6.3%) had repetitive prolapse of upper iris,2(1.4%) had comeal edma,11(7.7%) had mutilation of iris root including 7 lower iris root mutilation and 4 upper,1(0.7%) had anterior chamber hyphema and 11(7.7%) had upper incision leakage.There was no case with lens nucleus falling in vitreous cavity or epichoroidal explosive hemorrhage.Conclusions:Correct surgical indication,normalized and skilled surgery procedure and technique can decrease incidence of complication.Besides,handling complication in time is helpful in successful surgery.