Application of Neuroform3 Stent in Endovascular Embolization of Intracranial Acutely Ruptured Wide-Necked Aneurysms
王武,李明华,杜倬婴,王珏,周兵,徐浩文,程永德,张培蕾
DOI: https://doi.org/10.3969/j.issn.1008-794x.2009.01.002
2009-01-01
Abstract:Objective To evaluate the effect of endovascular Neuroform3 stent-assisted detachable coil embolization with and to make a mid-term follow-up observation. Methods The clinical results of emergent interventional embolization in 48 patients with intracranial acutely-ruptured wide-necked aneurysms, encountered in the past 18 months, were retrospectively analyzed, of which Neuroform3 stent-assisted detachable coil embolization was performed in 26 cases within 72 hours after the onset of the disease. The aneurysms located at the A1 segment of anterior cerebral artery (n = 3), the M1 and M2 segment of middle cerebral artery (n = 3), the posterior communicating artery (n = 13), the ophthalmic segment of internal carotid artery (n = 2), the top of basilar artery (n = 2), the V3 and V4 segment of vertebral artery (n = 2), or the posterior inferior cerebellar artery (n = 1). The stent was implanted after the first (n = 3), second (n = 1) or fourth (n = 2) coil was delivered. In 10 cases the first coil could not be formed in basket shape within the aneurysm sac. In the remaining 10 cases the stent implantation procedure was carried out before the coil embolization, and the microcatheter was successfully introduced into the aneurysm through the struts of the stent in all ten cases. Results Successful deployment of the Neuroform3 stent was obtained in all cases(100%), with the coil covering the neck of the aneurysm. The coils were positioned for all aneurysms in single session. Immediate angiography after the procedure showed that total occlusion was achieved in 23aneurysms (88.5%) and subtotal occlusion in 3 aneurysms (11.5%). During the whole procedure, the stent moved slightly in one case, no obvious thromboembolic or rebleeding event occurred. All patients showed a good recovery at the time of discharge. Follow-up could be conducted in 23 cases for a period over 18 months, cerebral angiography for check-up was made in 1 ~ 3 times. Complete occulusion was observed in 14 cases (60.8%). Of 6 cases whose aneurysm neck showed a little residual opacification, progressive thrombosis occurred in 3(11.5%). Of 3 cases with subtotal occulusion, stable condition was seen in 2 cases and recanalized aneurysm in one case. Delayed in-stent stenosis was observed in 2 cases (7.7%). Conclusion Neuroform3 stent-assisted detachable coil embolization is a simple, safe and effective method for the treatment of intracranial acutely-ruptured wide-necked aneurysms.