Assisted Coiling Techniques in Treatment of Intracraniai Complex Aneurysms

PAN Jian-wei,OU Chang-jiang,YAN Min,FAN Wei-jian,HE Hong-wei,WU Zhong-xue,ZHAN Ren-ya
DOI: https://doi.org/10.3760/cma.j.issn.1001-2346.2011.05.013
2011-01-01
Abstract:Objective To investigate the application of assisted coiling techniques in the treatment of complex intracranial aneurysms.Methods From Jun.2007 to Aug.2010,36 patients with 41 complex intracranial aneurysms were treated by varient endovascular methods,including balloon,stent-assisted coiling and double microcatheter coiling techniques.Results Among the 33 wide - neck aneurysms,11cases underwent balloon- assisted coiling,in which 7 were totally occluded,3 subtotally occluded,1 diverted to double microcatheter treatment after failure balloon placement.15 cases underwent stent - assisted coiling,in which 10 were totally occluded,2 subtotally or partially occluded respectively,1 by single stent placement without coiling.8 cases accepted double microcatheter treatment,6 were totally occluded,1 subtotally occluded and 1 partially occluded.All 8 fusiform aneurysms were treated by stent -assisted coiling,one case was totally occluded,6 subtotally occluded,and another one was treated by single stent placement.The complications were found in 3 patients,including intra - operative thrombosis in 2 cases and dysopia in one case.Conclusion Balloon,stent - assisted coiling and double microcatheter techniques are safe and effective in treating complex intracranial aneurysms,but it should be determined by the position and morphologic characteristics of aneurysms as well as the patients' clinical condition.
What problem does this paper attempt to address?