Use of the Glucose Oxidase System for Estimation of Oxygen Transfer Rate in A Solid-State Bioreactor

H Zhao,XY Zhang,XH Zhou,ZH Li
DOI: https://doi.org/10.1016/s0141-0229(02)00017-0
IF: 3.705
2002-01-01
Enzyme and Microbial Technology
Abstract:The glucose oxidase system was adapted for estimation of the overall oxygen transfer rate in a periodic pressure oscillating, solid-state bioreactor. Enzyme concentration of 40 ml enzyme preparation L−1 was found adequate to give linear gluconic acid production and attain maximal oxygen absorption rates. At 4 atm and 30°C, the oxygen transfer rate reached 892 mmol kg−1 initial dry matter h−1 in this system, while only 121 mmol kg−1 initial dry matter h−1 was obtained in a conventional static tray bioreactor.