Evaluation of Optimized B-Value Sampling Schemas for Diffusion Kurtosis Imaging with an Application to Stroke Patient Data.

Xu Yan,Minxiong Zhou,Lingfang Ying,Dazhi Yin,Mingxia Fan,Guang Yang,Yongdi Zhou,Fan Song,Dongrong Xu
DOI: https://doi.org/10.1016/j.compmedimag.2013.04.007
IF: 7.422
2013-01-01
Computerized Medical Imaging and Graphics
Abstract:Diffusion kurtosis imaging (DKI) is a new method of magnetic resonance imaging (MRI) that provides non-Gaussian information that is not available in conventional diffusion tensor imaging (DTI). DKI requires data acquisition at multiple b-values for parameter estimation; this process is usually time-consuming. Therefore, fewer b-values are preferable to expedite acquisition. In this study, we carefully evaluated various acquisition schemas using different numbers and combinations of b-values. Acquisition schemas that sampled b-values that were distributed to two ends were optimized. Compared to conventional schemas using equally spaced b-values (ESB), optimized schemas require fewer b-values to minimize fitting errors in parameter estimation and may thus significantly reduce scanning time. Following a ranked list of optimized schemas resulted from the evaluation, we recommend the 3b schema based on its estimation accuracy and time efficiency, which needs data from only 3 b-values at 0, around 800 and around 2600 s/mm2, respectively. Analyses using voxel-based analysis (VBA) and region-of-interest (ROI) analysis with human DKI datasets support the use of the optimized 3b (0, 1000, 2500 s/mm2) DKI schema in practical clinical applications.
What problem does this paper attempt to address?