Saturated Liquid Viscosity of Cyclopentane and Isopentane

RF Ma,L Shi,YY Duan,LZ Han,NX Liu
DOI: https://doi.org/10.1021/je0202174
2003-01-01
Abstract:In this paper, the saturated liquid viscosity of cyclopentane and isopentane was measured through the capillary flow method, over the temperature range from 253.15 K to 353.15 K. The results were correlated as a function of temperature. The viscometer was calibrated using water, ethanol, acetone, and ethyl acetate.