Effect of Relative Humidity on the Maximum Leakage Current of Insulators

MEI Hong-wei,MAO Ying-ke,BIAN Xing-ming,PENG Gong-mao,WANG Li-ming,GUAN Zhi-cheng
DOI: https://doi.org/10.13336/j.1003-6520.hve.2010.03.012
2010-01-01
Abstract:The maximum leakage current of insulators is closely linked to environmental factors,especially to the relative humidity.In this paper,three kinds of conventional insulators named XWP-70,XP-70 and LXY-70 were taken as the research objects to investigate the effects of environmental relative humidity on the maximum leakage current of insulators.A great deal of experiments using a reliability test method were carried out in a humidity controlled test chamber to investigate the relationship between the maximum leakage current of the insulators and the relative humidity under four kinds of equivalent salt deposit density(ESDD),then the curve for describing the relationship between them was obtained and displayed in the article.Based on the results presented above,the relationship between the maximum leakage current of insulators under low relative humidity and that under the saturated moisture was gained,and also the expression using the maximum leakage current measured under low relative humidity to estimate the maximum leakage current under the saturated moisture was brought forward.
What problem does this paper attempt to address?