Numerical Analysis on the Condensation Problem of Typical Self-thermal Insulation Wall with Aerated Concrete

Yuan ZHANG,Ben-li GAO,Kai DU
DOI: https://doi.org/10.3969/j.issn.1002-8528.2012.04.020
2012-01-01
Building Science
Abstract:Aerated concrete self-thermal insulation construction is one of the important self-thermal insulation construction styles of exterior wall.Whether the condensation phenomenon will happen on interior surface of thermal bridges of this kind of wall is an essential calculation section during the energy conservation design.In this paper,the CFD software Fluent and finite volume method were used to simulate the heat transfer process of the typical fly ash aerated concrete self-thermal insulation wall in winter in Nanjing,and the inner temperature field was obtained.The simulation results indicated that the minimum temperature points of interior surface located at the center vertical lines on the width of interior surface of thermal bridges and the inside corners,the condensation problem of these positions should be seriously considered.Furthermore,the minimum temperature values of interior surfaces of different aerated concrete self-thermal insulation constructions were larger than 13.5 ℃,which was higher than the dew-point temperature of indoor air,the condensation phenomenon would not happen.
What problem does this paper attempt to address?